Output Voltage | 220V |
Temperature Range | -200 to 850 Degree C |
Usage/Application | Industrial |
Power Frequency | 50-60 Hz |
Power Source | Electric |
Phase | 1 Phase |
Applications:
Specifications:
Conductivity | Range | .. to 19.99, 199.9, 1999 μS/cm ; 19.99, 199.9 mS/cm |
Resolution | 0.01, 0.1, 1 μS/cm ; 0.01, 0.1 mS/cm | |
Accuracy | ±1 % Full scale + 1 digit | |
Calibration | Up to 4 points (auto calibration), up to 5 points (manual) | |
TDS | Range | .. to 9.99, 99.9, 999 ppm ; 9.99, 99.9 ppt (Max. of 199.9 based on factor setting) |
Resolution | 0.01, 0.1, 1 ppm ; 0.01, 0.1 ppt | |
Accuracy | ± 1 % Full scale + 1 digit | |
Calibration | 5 Points (1 per range) | |
Temperature | Range | - 10.0 to 110.0 ºC / 14.0 to 230.0 ºF (Meter) |
Resolution | 0.1 ºC / 0.1 ºF | |
Accuracy | ± 0.5 ºC (± 0.9 ºF) | |
ATC | Yes (0 to 80 ºC) |
Model Name/Number | pH 700 |
Brand | Eutech |
Ph Range | -2.00 to 16.00 pH |
Temperature Accuracy | +-0.3 / +-0.5 Degree F (0 to 70 Degree Celsius) |
Temperature Resolution | 0.1 Degree Celsius / 0.1 Degree F |
ORP Accuracy | +-0.2 mV (+-199.9 mV) / +-2 mV (beyond) |
ORP Resolution | 0.1 mV (+-199.9 mV) / 1 mV (beyond) |
Temperature Range | 0.0 to 100.0 Degree Celsius / 32.0 to 212.0 Degree F |
Temperature Power Requirements | 9 V DC adapter, 1.3 A (100/240 VAC, SMPS) |
pH Resolution | 0.01 pH |
pH Accuracy | +-0.01 pH |
ORP Range | +-2000 mV |
Economical, user-friendly and accurate, the Eutech pH 700 is your ideal choice for routine applications in laboratories, productions plants and schools
Features:
Display Type | LED Display, LCD Display |
Ph Range | 0 to 14 |
Battery Type | 4 AAA x 1.4V batteries |
Temperature Accuracy | +-0.05 Degree Celsius |
mV Range | -1000 to 1000 mV |
Calibration Points | Up to 5 |
mV Accuracy | +-1 |
Temperature Resolution | 0.1 Degree Celsius |
pH Accuracy | +- 0.01 |
Features:
Model | EcoTestr EC Low |
Brand | Eutech |
Accuracy | +-1 % full scale (+-2 % above 10 mS/cm) |
Weight | 137 gm |
Power | 4 X 1.5 V "A76" Micro alkaline batteries |
Calibration Points | 1 (digital, push-button) |
Resolution | 0.1 mS/cm |
Ingress Rating | IP67 Waterproof |
Boxed Dimensions | 24.5 x 13.5 x 4.5 cm |
Auto-Off | 8.5 mins after last key pressed |
Range | 1990 mS/cm |
LCD Display | 3 1/2 digit with annunciator |
The Eutech EcoTestr EC series comes with rugged, sturdy stainless steel pin sensors, giving you quick, reliable conductivity measurements. Ideal for use in a wide range of conductivity applications, such as hydroponics gardening, fish-farming, pools, electroplating and other water/ wastewater applications.
Model Name/Number | CyberScan pH 510 |
Brand | Eutech |
Ph Range | 0.00 to 14.00 pH |
Power | 9VDC, using AC adapters 110VAC or 220VAC, 50/60 Hz |
Temperature Compensation | Automatic / Manual (0 to 100 Degree Celsius) |
Temperature Resolution & Accuracy | 0.1 & +-0.3 Degree Celsius |
No of Calibration Points | Up to 3 points |
Resolution & Accuracy | 0.01 & +-0.01 pH |
mV Resolution & Accuracy | 0.1 mV & +-0.2 mV (within +-199.9 mV); 1 mV & +-2 mV (beyond +-200 mV) |
Memory | 50 Data Sets |
mV Range | +-199.9 mV; +-1999 mV |
Temperature Range | 0.0 to 100.0 Degree Celsius |
Features:
Model Name/Number | EcoTestr EC High |
Resolution | 0.1 mS/cm |
Power | 4 X 1.5 V "A76" Micro alkaline batteries |
Accuracy | +-1 % full scale (+-2 % above 10 mS/cm) |
Range | 19.90 mS/cm |
Ingress Rating | IP67 Waterproof |
Calibration Points | 1 (digital, push-button) |
Brand | Eutech |
Auto-Off | 8.5 mins after last key pressed |
LCD Display | 3 1/2 digit with annunciator |
Country of Origin | Made in India |
Brand | Eutech |
Resolution | 0.1 pH |
Ph Range | -1.0 to 15.0 pH |
Battery Life | 3 x 1.4V (Type: A 76, LR44, V13GA) ; >60 hours |
Boxed Weight | 170 gm |
Model No | pHTestr 1, 2 |
Tester Dimension | 15 x 3.8 cm |
Tester Weight | 90 g |
Boxed Dimension | 18.5 x 7 x 5 cm |
Model Name/Number | CyberScan pH 110 |
Brand | Eutech |
Battery Life | > 700 hours |
Temperature Compensation | Automatic / manual (from 0 to 100 Degree Celsius) |
Meter Weight | 290g |
Boxed Dimensions | 24 x 23 x 7 cm |
Boxed Weight | 650g |
Auto Power-off | After 20 minutes (selectable) |
Display | Custom Dual LCD |
Meter Dimensions | 18.7 x 9 x 4 cm |
Power Requirements | 4 'AAA' alkaline batteries, AC / DC adapter 9V, 200 mA |
Features:
Model Name/Number | CON 700 |
Brand | Eutech |
Temperature Accuracy | +- 0.5 Degree Celsius / +- 0.9 Degree F |
TDS Resolution | 0.01 / 0.1 / 1 ppm ; 0.01 / 0.1 ppt |
Temperature Range | 0.0 to 100.0 Degree Celsius / 32.0 to 212.0 Degree F |
TDS Range | 100.0 ppt at 0.5 fact (200.0 at 1 factor) |
Conductivity Range | 200.0 mS |
Conductivity Accuracy | +-1 % full scale |
Conductivity Resolution | 0.01 / 0.1 / 1 MS ; 0.01 / 0.1 mS |
TDS Accuracy | +- 1 % full scale |
Temperature Resolution | 0.1 Degree Celsius / 0.1 Degree F |
The economy Eutech CON 700 offers years of reliable, accurate and consistent performance. User-friendly features make the instrument an ideal research partner in laboratories, productions plants and schools.
Model Name/Number | CON-2700 |
Brand | Eutech |
Conductivity Cell Constant | 0.010 to 10.000 |
Salinity Accuracy | +-1 % full scale |
TDS Range | 0.050 ppm to 500 ppt |
TDS Resolution | 0.01 / 0.1 ppm ; 0.001 / 0.01 / 0.1 ppt |
Conductivity Accuracy | +-1 % full scale |
Conductivity Range | 0.050 mS to 500.0 mS |
TDS Accuracy | +-1 % full scale |
Salinity Range | 0.0 to 80.0 ppt |
Salinity Resolution | 0.01 / 0.1 ppm ; 0.001 / 0.01 / 0.1 ppt |
Country of Origin | Made in India |
Applications:
Model Name/Number | PH 5+ |
Brand | Eutech |
Ph Range | 0.00 to 14.00 pH |
Power | 4 'AAA' x 1.4V batteries |
Temperature Compensation | Automatic / Manual (0 to 100 Degree Celsius) |
No of Calibration Points | 2 to 5 points |
pH Resolution and Accuracy | 0.01 pH & +- 0.01 pH |
pH Temperature Range | 0 to 100.0 Degree Celsius |
Country of Origin | Made in India |
Product Features
Brand | Eutech |
Power | 4 x 1.5 V 'AAA' alkaline batteries |
Memory | 50 data sets |
Temperature Accuracy | +-0.5 Degree Celsius / +-0.9 Degree F |
Temperature Resolution | 0.1 Degree Celsius / 0.1 Degree F |
Meter dimensions | 19 x 10 x 6 cm |
Model No | CON 410 |
TDS Accuracy | +/-1 % full scale + 1 LSD |
Temperature Compensation | ATC / MTC (0 to 80 Degree Celsius) |
Input | 6-pin connector |
TDS Resolution | 0.05 % full scale |
Auto-Off | 20 mins after last key pressed |
Meter Weight | 320 g |
TDS Factor | 0.40 to 1.0 |
Cell Constant | 0.1, 1.0, 10.0 |
LCD Display | Dual-display LCD (5.8 x 3.3 cm) |
Temperature Normalization | 15 to 30 Degree Celsius |
Temperature Range | 0.0 to 100.0 Degree Celsius; 32.0 to 212 Degree F |
Conductivity Resolution | 0.05 % full scale |
Conductivity Accuracy | +-1 % full scale + 1 LSD |
Battery Life | 100 hrs |
Country of Origin | Made in India |
Brand | Eutech |
Power | 4 'AAA' x 1.4V batteries |
Cell Constant | 0.1, 1.0, 10.0 (selectable) |
Model No | TDS 6+ |
Resolution & Accuracy | 0.1 & +- 0.5 Degree Celsius |
Temperature Coefficient | 2%/ Degree Celsius |
No of Calibration Points | Up to 5 max. (1 per range) |
Resolution & Accuracy | 0.01, 0.1, 1 ppm & 0.01, 0.1, 1 ppt; +-1% Full Scale |
TDS Factor | 0.40 to 1.00 (default 0.67) |
Temperature Range | 0 to 100.0 Degree Celsius |
Temperature Compensation | Automatic / Manual (0 to 80 Degree Celsius) |
Model Name/Number | EcoTestr Salt |
Weight | 137 g |
Resolution | 0.1 ppt |
Brand | Eutech |
Power | 4 X 1.5 V "A76" Micro alkaline batteries |
Accuracy | +-1 % full scale (+-2 % above 5 ppt) |
Range | 10.00 ppt |
Application | Laboratory |
Auto-Off | 8.5 mins after last key pressed |
LCD Display | 3 1/2 digit with annunciator |
Boxed Dimensions | 24.5 cm x 13.5 cm x 4.5 cm |
Ingress Rating | IP67 Waterproof |
Calibration Points | 1 (digital, push-button) |
TDS Factor | Non-linear compensation |
Country of Origin | Made in India |
Brand | Eutech |
Material | ABS Plastic |
Power | 4 'AAA' x 1.4V batteries or 9VDC power adapter |
Memory | 50 data sets |
Model No | CyberScan CON 11 |
TDS Range | 0 to 9.99, 99.9, 999 ppm; 9.99, 99.9 ppt |
Cell Constant | 0.1, 1.0, 10.0 (selectable) |
Resolution & Accuracy | 0.05% Full Scale & +-1% Full Scale + 1 LSD |
Calibration for Conductivity | Automatic (single or multi-point up to 4 points) / Manual (up to 5 points) |
Calibration for TDS | Manual (up to 5 points - 1 per range) |
Temperature Range | -10.0 to 110.0 Degree Celsius (Meter) |
No of Calibration Points | Up to 5 points (1 per range) |
Conductivity Range | 0 to 19.99, 199.9, 1999 MS/cm; 19.99, 199.9 mS/cm |
Normalization Temperature | 20.0 or 25.0 Degree Celsius |
Temperature Coefficient | 0.0 to 10.0%/Degree Celsius |
TDS Factor | 0.40 to 1.00 (selectable) |
Model Name/Number | EcoTestr pH 1 |
Brand | Eutech |
Weight | 137 g |
Resolution | 0.1 pH |
Type | Digital |
Ph Range | 0.0 to 14.0 pH |
Power | 4 X 1.5 V "A76" Micro alkaline batteries |
Accuracy | +-0.1 pH |
pH Calibration Points | 1 (Auto) |
Auto-Off | 8.5 mins after last key pressed |
Ingress Rating | IP67 Waterproof |
LCD Display | 3 1/2 digit with annunciator |
Dimensions | 24.5 x 13.5 x 4.5 cm |
Operating Temperature | 0 to 50 Degree Celsius |
Country of Origin | Made in India |
Model Name/Number | pH 1500 |
Brand | Eutech |
Ph Range | -1.999 to 19.999 pH |
Temperature Compensation | Automatic/Manual (0 to 100 Degree Celsius) |
Memory | 100 Data Sets |
mV Range | -1800 to +1800 mV |
Temperature Range | -5.0 to +105.0 Degree Celsius (23.0 to +221.0 Degree F) |
Print Output | RS232C |
Display | LCD - 105 X 75 mm |
No of Calibration Points | Up to 6 points |
Resolution & Accuracy | 0.1/0.01/0.001 & +-0.1/0.01/0.002 pH |
Brand | Eutech |
Usage | Laboratory |
Model | CON 6 |
Power | 4 'AAA' x 1.4V batteries |
Resolution & Accuracy | 0.01, 0.1, 1 mS/cm & 0.01, 0.1 mS/cm; +-1% Full Scale + 1 LSD |
Temperature Compensation | Automatic / Manual (0 to 80 Degree Celsius) |
No of Calibration Points | Up to 5 max. (1 per range) |
Cell Constant | 0.1, 1.0, 10.0 (selectable) |
Temperature Coefficient | 2% / Degree Celsius |
Conductivity Range | 0 to 19.99, 199.9, 1999 mS/cm; 19.99, 199.9 mS/cm |
Temperature Range | 0 to 100.0 Degree Celsius (Meter) |
Product Features:
Model Name/Number | ION 700 |
Brand | Eutech |
Ph Range | -2.00 to 16.00 pH |
Temperature Accuracy | +-0.3 / +-0.5 Degree F (0 to 70 Degree Celsius) |
Temperature Range | 0.0 to 100.0 Degree Celsius / 32.0 to 212.0 Degree F |
ORP Resolution | 0.1 mV (+-199.9 mV) / 1 mV (beyond) |
ORP Accuracy | +-0.2 mV (+-199.9 mV) / 2 mV (beyond) |
Ion Resolution | 0.01 / 0.1 / 1 ppm |
Ion Accuracy | +-0.5 % full scale (monovalent) +-1 % full scale (divalent) |
Ion Concentration | 0.01 to 2000 ppm (+-2000 mV) |
Temperature Power Requirements | 9 V DC adapter, 1.3 A (100/240 VAC, SMPS) |
pH Resolution | 0.01 pH |
ORP Range | +-2000 mV |
pH Accuracy | +-0.01 pH |
Temperature Resolution | 0.1 Degree Celsius / 0.1 Degree F |
Country of Origin | Made in India |
ION 700 | ||
pH | Range | 0.00 to 14.00 pH |
Resolution | 0.01 pH | |
Accuracy | ±0.002 | |
Cal.Points | Up to 5 points | |
Buffer Sets | USA, NIST | |
ORP | Range | ±1999 mV |
Rel. MV Range | ±1999 mV | |
Resolution | 0.1 mV (±199.9 mV) / 1 mV (beyond) Accuracy |
|
Accuracy | ±0.2 mV (±199.9 mV) / ±2 mV (beyond) | |
ION | Concentration | 0.01 to 2000 ppm |
Resolution (ppm) | 0.01 (<1); 0.1 (1.0 to 199.9); 1 (>200) | |
Accuracy | ±0.5 % full scale (monovalent) ±1.0 % full scale (divalent | |
Cal.Points | From 2 to 5 consecutive points; 0.1, 1.0, 10.0, 100.0 or 1000.0 ppm | |
Temperature | Range | 0.0 to 100.0 ºC / 32.0 to 212.0 ºF |
Resolution | 0.1 ºC / 0.1 ºF | |
Accuracy | ±0.5 ºC / ±0.9 ºF | |
Compensation | Automatic or Manual (0 to 100 ºC / 32 to 212 ºF) | |
Calibration | Offset in 0.1 º increments; offset range: ± 5 ºC / 9 ºF |
Model Name/Number | pH 2700 |
Brand | Eutech |
Ph Range | -2.000 to 20.000 pH |
Temperature Compensation | ATC / MTC |
Temperature Accuracy | +-0.3 Degree Celsius / +-0.5 Degree F |
ORP Accuracy | +-0.2 mV |
Temperature Resolution | 0.1 Degree Celsius / 0.1 Degree F |
pH Accuracy | +-0.002 pH + 1 LSD |
ORP Resolution | 0.1 mV |
Temperature Range | 0.0 to 100.0 Degree Celsius / 32.0 to 212.0 Degree F |
Temperature Power Requirements | 9 V DC adapter, 1.3 A (100/240 VAC, SMPS) |
ORP Range | +-2000.0 mV |
pH Resolution | 0.1 / 0.01 / 0.001 pH |
pH Buffer Sets | USA, NIST, DIN, User 1, User 2, Custom |
Specifications:
pH | Range | -2.000 to 20.000 pH |
Resolution | 0.1 / 0.01 / 0.001 pH | |
Accuracy | ±0.002 pH + 1 LSD | |
Cal. Points | Up to 6 preset or 5 custom | |
Buffer Sets | USA, NIST, DIN, User 1, User 2, Custom | |
ORP | Range | ±2000.0 mV |
Rel.mV Range | ±2000.0 mV | |
Resolution | 0.1 mV | |
Accuracy | ±0.2 mV | |
ION | Concentration | - |
Accuracy | - | |
Cal. Points | - | |
Temperature | Range (Meter) | 0.0 to 100.0 ºC / 32.0 to 212.0 ºF |
Resolution | 0.1 ºC / 0.1 ºF | |
Accuracy | ±0.3 ºC / ±0.5 ºF | |
Compensation | ATC / MTC |
Model Name/Number | ION 2700 |
Brand | Eutech |
Ph Range | -2.000 to 20.000 pH |
Temperature Accuracy | +-0.3 Degree Celsius / +-0.5 Degree F |
ORP Accuracy | +-0.2 mV |
Temperature Power Requirements | 9 V DC adapter, 1.3 A (100/240 VAC, SMPS) |
pH Accuracy | +-0.002 pH + 1 LSD |
ORP Resolution | 0.1 mV |
Ion Accuracy | 0.5 % full scale (monovalent) ; 1 % full scale (divalent) |
Temperature Range | 0.0 to 100.0 Degree Celsius / 32.0 to 212.0 Degree F |
Temperature Resolution | 0.1 Degree Celsius / 0.1 Degree F |
ORP Range | +-2000.0 mV |
Ion Resolution | 2 or 3 digits |
Ion Concentration | 0.001 to 19999 ppm (+-2000 mV) |
pH Resolution | 0.1 / 0.01 / 0.001 pH |
Applications:
Brand | Eutech |
Model Name/Number | TN-100 |
Range | 0 to 2000 NTU |
Light Source | Infrared-emitting diode (850 nm wavelength) |
Enclosure Type & Rating | ABS plastic & IP67 rated |
Operating Temperature Range | 0 to 50 Degree Celsius |
Measuring Parameter | Turbidity |
Response Time | < 6 secs for full step change |
Meter Dimensions | 15.5 x 6.8 x 4.6 cm (L x W x H) |
Boxed Dimensions | 35.5 x 16.5 x 10.5 cm (L x W x H) |
Highlights | Light weight, IP67 waterproof meter |
Calibration | Up to 4 points |
Calibration Standards | 0.02 NTU, 20.0 NTU, 100 NTU, 800 NTU |
Principle | Nephelometric non-ratio / ISO 7027 and DIN 27027 compliant |
Boxed Weight | 1160 g |
Repeatability | < or = +-1 % of reading |
Sample Volume | 10 ml |
Power | 4 x 1.5 V 'AAA' alkaline batteries (> 1200 readings) |
Meter Weight | 200 g |
Country of Origin | Made in India |
Brand | Eutech |
Model Name/Number | COND 610 |
Power | 4 'AAA' x 1.4V batteries or 9VDC power adapter |
Input | DC phono sockets, 8-pin connector |
LCD Display | Back-lit Dot Matrixq |
Salinity | 80 ppt |
Cal Due Alarm | Yes (Days - Max 30) |
Resisitivity Temperature Range | -10.0 to 110.0 Degree Celsius (14.0 to 230 Degree F) (Meter) |
Salinity Resolution & Accuracy | 0.05% & +-1% Full Scale + 1 LSD |
Salinity Resolution and Accuracy | 0.05% & +-1% Full Scale |
Ingress Protection | IP67 |
Memory | 500 data sets |
TDS | 500 ppt |
Conductivity Range | 500.0 mS |
Brand | Eutech |
Power | 4 'AAA' x 1.4V batteries or 9VDC power adapter |
Memory | 100 data sets |
Model No | CON 110 |
Temperature Coefficient | 0.0 to 10.0%/ Degree Celsius |
TDS Resolution and Accuracy | 0.05% Full Scale & +-1% Full Scale + 1 LSD |
TDS Temperature Range | -10.0 to 110.0 Degree Celsius (14.0 to 230 Degree F) (Meter) |
No of Calibration Points | Up to 5 points (1 per range) |
Conductivity Range | 0 to 19.99, 199.9, 1999 mS/cm; 19.99, 199.9 mS/cm |
Normalization Temperature | 20.0 or 25.0 Degree Celsius |
Cell Constant | 0.1, 1.0, 10.0 |
TDS Range | 0 to 9.99, 99.9, 999 ppm; 9.99, 99.9 ppt |
Temperature Compensation | Automatic / Manual (0 to 100 Degree Celsius ) |
Calibration for Conductivity | Automatic (single or multi-point up to 4 points) / Manual (up to 5 points) |
TDS Factor | 0.40 to 1.00 |
Display Resolution | 160 x 240 pixels |
Battery Life | 20 hours |
Battery Type | 2 AA batteries (not included); NiMH or Lithium recommended |
Display Size | 1.43 x 2.15 inch |
Weights | 218.3 gm |
Display Type | Transflective, 65-K color TFT |
Waterproof | IPX7 |
Dimensions | 6.6 x 15.2 x 3.0 cm |
Country of Origin | Made in India |
Brand | Eutech |
Model | CON 1500 |
Usage | Laboratory, Industrial |
Display Type | Digital |
TDS Factor | 0.40 to 1.00 |
Temperature Range | -5.0 to 105.0 Degree Celsius (23.0 to 221.0 Degree F) (Meter) |
Temperature Coefficient | 0 to 10.0 % Degree Celsius |
Resolution | 0.1 Degree Celsius (0.1 Degree F) |
Conductivity Range | 0.000 to 500.0 mS/cm |
TDS Range | 0.000 to 99'999 ppm |
Resolution | +-0.01% full scale |
Accuracy | +-0.5% full scale |
Memory | 100 Data Sets |
Normalization Temperature | 15.0 to 30.0 Degree Celsius (59.0 to 86.0 Degree F) |
Calibration Options | Automatic (single or multi-point up to 4 points) & manual (up to 5 points - 1 per range) |
Power Requirement | 110VAC/ 220VAC, centre negative |
Model Name/Number | CON 6000 |
Brand | Eutech |
Accuracy | 0.5% full scale + 1 LSD |
Resolution | +-0.01% full scale reading |
Temperature Range | -5.0 to +105.0 degree Celsius (Meter) |
Cell Constant | 0.1, 1.0, 10.0 |
Temperature Coefficient | 0.000 to 10.000 % |
Tds Range | 0.0 to 500.0 ppt |
Conductivity Range | 0.000 to 500.0 mS/cm |
Memory | 10,000 Data Sets |
Resistivity Range | 3 ohm-cm to 100 megohm-cm |
Normalization Temperature | 15.0 to 30.0 Degree Celsius |
Display | 640 x 480 digit LCD |
Power Requirement | 9VDC, 3.3A center negative |
Country of Origin | Made in India |
Packaging Size | 480 ml |
Brand | Eutech |
Usage | Laboratory |
Packaging Type | Bottle |
Form | Liquid |
Purity | 99% |
Country of Origin | Made in India |
Product Features:
Model Name/Number | CyberScan PCD 6500 |
Brand | Eutech |
Accuracy | 0.5% full scale + 1 LSD |
Temperature Range | -5.0 to 105.0 degree Celsius (Meter) |
Cell Constant | 0.1, 1.0, 10.0 |
Resolution & Accuracy | 0.1/0.01/0.001 pH & +-0.002 pH |
Conductivity Range | 0 to 500 mS/cm |
Resistivity Range | 3 ohm cm to 100 megohm cm |
Salinity Range | 0 to 90 ppt |
DO Range | 0 to 60 ppm, 0 to 600% |
mV Range | -1800 to +1800 mV |
pH Range | -2.000 to 20.000 pH |
Country of Origin | Made in India |
Display | 4-digit 14-segments customized liquid crystal display with annunciators |
Brand | Eutech |
Model No / Item Code | C401 |
Detector | Silicon Photodiode |
Light Source | Light Emitting Diode (LED) |
Power Supply | 4 'AAA' alkaline batteries |
Weight Instrument | 200g |
Measurement Method | Photometric |
Operating Humidity Range | 0-90% RH non-condensing at 30 Degree Celsius |
Wavelength | 525 nm |
Electromagnetic | EN 61326 Compliance (EMC) |
Dimensions Instrument | 6.8 x 15.5 x 4.6 cm (W x L x H) |
Calibration Points | User selectable; 1 point per colorimetric test |
Sample Volume Required | 10 ml |
Battery Life | > 3000 tests |
Operating Temperature Range | 0 - 50 Degree Celsius |
Absorbance Range | 0 - 2.5 Abs |
Photometric Precision | +-0.0015Abs |
Complete Carrying Case | 1.25 kg |
Eutech’s latest range of laboratory grade microprocessorbased portable waterproof colorimeters measure Chlorine (Free and Total), Cyanuric Acid, pH, Chlorine Dioxide, Bromine and Ozone with quick, accurate and repeatable results. The meters are easy to use because of their simple, intuitive and direct user interface. Guiding messages and self-diagnostics are displayed on a large custom-made liquid crystal display (LCD). Each meter comes with reagents and sample vials ina rugged carrying case for swift testing on the go. This family of colorimeters is designed for reliable and convenient water analysis in swimming pools, spas, public utilities, industrial wastewater plants, municipal water, treated water, water conditioning systems and paper and pulp mills. Select from our wide range of models, designed to meet your application needs.
Product Features:
Model | pH 6500 |
Brand | Eutech |
Temperature Range | -5.0 to 105.0 Degree Celsius (Meter) |
Cell Constant | 0.1, 1.0, 10.0 |
Power | 9VDC, 3.3A center negative |
Salinity Resolution & Accuracy | 0.1 mV & +-0.2 mV |
pH Range | -2.000 to 20.000 pH |
Operating Temperature | 0 to 50 Degree Celsius |
mV Range | +-2000.0 mV |
mV Conductivity Range | 0 to 500 mS/cm over 4 ranges |
Salinity Accuracy | 0.5% full scale + 1 LSD |
Print Interval | 3 to 86400 sec |
Electrode Input | FET (solid-state non-glass) or Glass pH electrode |
Display | 640x480 digit LCD |
Print Output | RS232C |
Salinity Range | 0 to 90 ppt |
mV Resistivity Range | 3 ohm-cm to 100 megohm-cm |
pH Resolution & Accuracy | 0.1/0.01/0.001 pH & +-0.002 pH |
Model Name/Number | CON 510 |
Brand | Eutech |
Accuracy | +- 1% Full Scale + 1 LSD |
Resolution | 0.05% of Full Scale |
Temperature Range | -10.0 to 110.0 Degree Celsius (14.0 to 230 Degree F) (Meter) |
Cell Constant | 0.1, 1.0 or 10.0 (selectable) |
Power | 9VDC, using AC adapters 110VAC or 220VAC, 50/60 Hz |
Conductivity Range | 0 to 20.00, 200.0, 2000 mS/cm; 20.00, 200 mS/cm |
Memory | 50 Data Sets |
Normalization Temperature | 15.0 to 30.0 Degree Celsius |
Country of Origin | Made in India |
Product Features:
Brand | Eutech |
pH Range | -2.000 to 20.000 pH |
mV Conductivity Range | 0 to 500 mS/cm over 4 ranges |
Print Interval | 3 to 86400 sec |
Accuracy | 0.5% full scale + 1 LSD |
Power | 9VDC, 3.3A center negative |
pH Resolution & Accuracy | 0.1/0.01/0.001 pH & +-0.1/0.01/0.002 pH + LSD |
Resistivity Range | 3 ohm-cm to 100 megohm-cm |
Print Output | RS232C |
Electrode Input | FET (solid-state non-glass) or Glass pH electrode |
Operating Temperature | 5 to 45 Degree Celsius |
Model No | CyberScan PC 6000 |
mV Range | +-2000.0 mV |
Salinity Range | 0 to 90 ppt |
Display | 640x480 digit LCD |
Country of Origin | Made in India |
Features:
Brand | Eutech |
Model Name/Number | Salt 6+ |
Power | 4 'AAA' x 1.4V batteries |
Salinity Range | 1 to 50.0 ppt; 0.1 to 5.00 % |
TDS Factor | Non-linear compensation |
Temperature Range | 0 to 100.0 Degree Celsius |
Resolution & Accuracy | 0.1 ppt; 0.01% & +-1% Full Scale |
Temperature Compensation | Automatic / Manual (0 to 80 Degree Celsius) |
Temperature Coefficient | 2% Degree Celsius |
No of Calibration Points | 1 point |
Brand | Eutech |
Model Name/Number | Salt 11 |
Resolution | 0.10 ppt |
Accuracy | +- 1% of Full Scale |
Calibration Point | 1 Point |
Battery Life | More than 150 hours |
Temperature Coefficient | 2% per Degree Celsius |
Auto Off | 8.5 minutes after last key pressed |
Tester Weight | 90 gm |
Boxed Dimension | 22 x 6 x 5 cm |
Operating Temperature | 0 to 50 Degree Celsius |
Power Battery | 4 x 1.5V 'A 76' micro Alkaline Batteries |
Tester Dimension | 16.5 x 3.8 cm |
Non-Volatile Memory | Yes |
ATC | Yes (0 to 50 Degree Celsius) |
Range | 0 to 10.00 ppt |
Boxed Weight | 170 gm |
Normalization Temperature | 25.0 Degree Celsius |
Country of Origin | Made in India |
Applications:
mV Accuracy | +-2mV |
Max Temperature | 110 Degree Celsius (230 Degree F) |
Output Alarm | 2 SPDT (120vAC, 6A) |
Display Type | LED |
Min mV | -1000 mV |
Temperature Accuracy | +-0.5 Degree Celsius |
Housing Material | 1/8-DIN |
Max pH | 14pH |
Max mV | 1000 mV |
mV Resolution | 1mV |
Output Current | 4-20mA |
Control Type | On/Off |
pH Resolution | 0.01 |
pH Accuracy | +-0.01 pH unit |
Min Temperature | -10 Degree Celsius (14 Degree F) |
Temperature Resolution | 0.1 Degree Celsius |
Password Protection | Yes |
Output Relay | 2 SPDT relays |
Country of Origin | Made in India |
This compact and economical controller has removable terminal strips and accepts power input between 85 to 250 VAC/DC for simple installation. The scrolling 14-segment LED display guides the user through setup, calibration, and operation functions. Setup and calibration modes are password-protected to prevent unauthorized changes. Operator can review previous calibration points and the electrode slope and offset for diagnostic purposes. The controller can be set for automatic or manual temperature compensation depending upon the application. The user can select one- or two-point calibration at seven common buffer values. Two independently programmable relays can be customized for set points and hysteresis. LED enunciators on the front panel indicate operation mode, measured parameter, and relay status. A galvanically isolated, 4 to 20 mA output is available for logging purposes. Order 100Ω Pt RTD, tinned-end electrodes with BNC pH connectors separately.
Model Name/Number | CyberScan COND 600 |
Temperature Range | -10.0 to 110.0 Degree Celsius (14.0 to 230 Degree F) (Meter) |
Brand | Eutech |
Ingress Protection | IP67 |
TDS | 200 ppt |
LCD Display | Back-lit Dot Matrix |
Memory | 500 data sets |
Conductivity Range | 200.0 mS |
Input | DC phono sockets, 8-pin connector |
Power | 4 'AAA' x 1.4V batteries or 9VDC power adapter |
Temperature Compensation | Automatic / Manual (0 to 100 Degree Celsius) |
Applications:
Environmental: Use to test water quality, monitor health of aquatic ecosystems, survey surface and ground water drinking supplies and to meet EPA regulations.
Industrial: Ideal for checking quality of plant water intake and discharge, wastewater and water treatment, recirculating systems and industrial process systems, water conditioning plants and chemical process verification.
Aqua cultural: Use to monitor water conditions in catfish and shrimp farming, game stocking ponds, ornamental fish tanks and ponds as well as other fish farming applications.
Model Name/Number | Temp 300 |
Brand | Eutech |
Input | Two thermocouple with ANSI connector |
Storage Temperature | -40 to 65 Degree Celsius (-40 to 149 Degree F); 10 % to 90 % (non-condensing) |
Dimensions | 175 x 97 x 42 mm |
LCD | 58 x 40 mm with backlight |
Min/Max Reading | Yes |
Power Requirements | 3 'AA' 1.5 V alkaline; >750 hours (without backlight) |
Weight | 267 gm |
Auto Shut-Off | 17.5 min (selectable) |
Country of Origin | Made in India |
Model Name/Number | PCD 6500 |
Brand | Eutech |
Accuracy | 0.5% full scale + 1 LSD |
Temperature Range | -5.0 to 105.0 Degree Celsius (Meter) |
Cell Constant | 0.1,1.0,10.0 |
Power | 9VDC,3.3A center negative |
Display | 640 x 480 digit LCD |
DO Testing | 5-day BOD,OUR and SOUR testing |
Conductivity Range | 0 to 500 mS/cm |
Automatic Barometric Pressure Compensation | 450 to 825 mmHg |
Output | USB,IRDA,RS232C |
pH Range | -2.000 to 20.000 pH |
Print Interval | 3 to 86400 sec |
Resolution & Accuracy | 0.1/0.01/0.001 pH & +-0.002 pH |
Electrode Input | FET (solid-state non-glass) or Glass pH electrode |
DO Range | 0 to 60 ppm,0 to 600% |
Salinity Range | 0 to 90 ppt |
mV Range | -1800 to +1800 mV |
Memory | 10,000 Data Sets with Date/Time stamping |
Resistivity Range | 3 ohm cm to 100 megohm cm |
Country of Origin | Made in India |